Resultados 1 - 18 de 18
Filtrar
1.
Front Oncol ; 13: 1270677, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38074663

RESUMO

Purpose: We aimed to retrospectively analyzed the feasibility of fast four-dimensional computed tomography (4DCT)-based O-ring LINAC treatment for patients with an average respiratory amplitude was< 0.5 cm and who cannot endure long treatment times due to poor performance status in lung 4D-stereotactic body radiotherapy (SBRT). Methods: This study included data of 38 patients who received lung 4D-SBRT and had average respiratory amplitude< 0.5 cm in the full phase. C-arm LINAC plans were based on 4DCT data obtained at phase values ranging from 20-70% using a C-arm LINAC. O-ring LINAC plans were retrospectively established based on 4DCT data obtained at phase values of 0-90% using an O-ring LINAC. The conformity index (CI), homogeneity index (HI), and gradient measurement of the planning target volumes (PTV) were analyzed to compare dosimetric data between C-arm LINAC and O-ring LINAC plans. Organs at risk were analyzed in accordance with the Radiation Therapy Oncology Group 0915 protocol. Treatment delivery time and total monitor units were analyzed to compare the efficiency of treatment delivery. Statistical comparisons were performed using the Wilcoxon signed-rank test (P< 0.05). Results: For the PTV, there was no significant difference in the CI or HI between C-arm LINAC and O-ring LINAC plans. For organs-at-risk, all plans met the criteria for dose constraint. There was a significant difference between C-arm LINAC and O-ring LINAC plans except in the spinal cord. Treatment delivery time was 92% longer for C-arm LINAC plans than for O-ring LINAC plans. The total MU value for C-arm LINAC plans was 9.6% higher than that for O-ring LINAC plans. Conclusion: We verified the feasibility of fast 4DCT-based O-ring LINAC treatment for patients with average respiratory amplitude< 0.5 cm and who cannot endure long treatment times due to poor performance status in lung 4D-SBRT.

2.
PLoS One ; 17(3): e0265143, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35353847

RESUMO

This study aimed to evaluate the quality of low-dose-rate (LDR) prostate brachytherapy (BT) based on treatment-related dosimetric outcomes. Data of 100 patients treated using LDR BT with stranded seeds from November 2012 to November 2017 were collected. The prescription dose for the prostate was 145 Gy. The dose constraints for the preoperative plan were: V100% ≥ 95%, V150% ≤ 60%, V200% ≤ 20% for the prostate; V100% for rectum, ≤ 1 cc; and V200 Gy for urethra, 0.0 cc. Intraoperative real-time dose calculation and postoperative dose distribution analysis on days 0 and 30 were performed. Median dosimetric outcomes on days 0 and 30 respective were: V100% 92.28% and 92.23%, V200% 18.63% and 25.02%, and D90% 150.88 Gy and 151.46 Gy for the prostate; V100% for the rectum, 0.11 cc and 0.22 cc; and V200 Gy for the urethra, 0.00 cc and 0.00 cc, respectively. Twenty patients underwent additional seed implantation to compensate for insufficient dose coverage of the prostate. No loss or substantial migration of seeds or severe toxicity was reported. With stranded seed implantation and intraoperative optimization, appropriate dose delivery to the prostate without excessive dose to the organs at risk could be achieved.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/efeitos adversos , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Próstata/cirurgia , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reto
3.
Technol Cancer Res Treat ; 21: 15330338221078464, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35167403

RESUMO

Purpose: Various deformable image registration (DIR) methods have been used to evaluate organ deformations in 4-dimensional computed tomography (4D CT) images scanned during the respiratory motions of a patient. This study assesses the performance of 10 DIR algorithms using 4D CT images of 5 patients with fiducial markers (FMs) implanted during the postoperative radiosurgery of multiple lung metastases. Methods: To evaluate DIR algorithms, 4D CT images of 5 patients were used, and ground-truths of FMs and tumors were generated by physicians based on their medical expertise. The positions of FMs and tumors in each 4D CT phase image were determined using 10 DIR algorithms, and the deformed results were compared with ground-truth data. Results: The target registration errors (TREs) between the FM positions estimated by optical flow algorithms and the ground-truth ranged from 1.82 ± 1.05 to 1.98 ± 1.17 mm, which is within the uncertainty of the ground-truth position. Two algorithm groups, namely, optical flow and demons, were used to estimate tumor positions with TREs ranging from 1.29 ± 1.21 to 1.78 ± 1.75 mm. With respect to the deformed position for tumors, for the 2 DIR algorithm groups, the maximum differences of the deformed positions for gross tumor volume tracking were approximately 4.55 to 7.55 times higher than the mean differences. Errors caused by the aforementioned difference in the Hounsfield unit values were also observed. Conclusions: We quantitatively evaluated 10 DIR algorithms using 4D CT images of 5 patients and compared the results with ground-truth data. The optical flow algorithms showed reasonable FM-tracking results in patient 4D CT images. The iterative optical flow method delivered the best performance in this study. With respect to the tumor volume, the optical flow and demons algorithms delivered the best performance.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Algoritmos , Marcadores Fiduciais , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem
4.
PLoS One ; 16(2): e0246845, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33596210

RESUMO

This study evaluates the changes occurring in the X-ray energy of a linear accelerator (LINAC) using a Daily QA3 detector system. This is accomplished by comparing the Daily QA3 results against those obtained using a water phantom. The X-energy levels of a LINAC were monitored over a duration of 1 month using the Daily QA3 system. Moreover, to account for the uncertainty, the reproducibility of the Daily QA3 ionization-chamber results was assessed by performing repeated measurements (12 per day). Subsequently, the energy-monitoring results were compared with the energy-change results calculated using the water-phantom percentage depth dose (PDD) ratio. As observed, the 6- and 10-MV beams experienced average daily energy-level changes of (-0.30 ± 0.32)% and (0.05 ± 0.38)%, respectively, during repeated measurements. The corresponding energy changes equaled (-0.30 ± 0.55)% and (-0.05 ± 0.48)%, respectively, when considering the measurement uncertainty. The Daily QA3 measurements performed at 6 MV demonstrated a variation of (2.15 ± 0.81)% (i.e., up to 3%). Meanwhile, the corresponding measurements performed using a water phantom demonstrated an increase in the PDD ratio from 0.577 to 0.580 (i.e., approximately 0.5%). At 10 MV, the energy variation in the Daily QA3 measurements equaled (-0.41 ± 0.82)% (i.e., within 1.5%), whereas the corresponding water phantom PDD ratio remained constant at 0.626. These results reveal that the Daily QA3 system can be used to monitor small energy changes occurring within radiotherapy machines. This demonstrates its potential for use as a secondary system for monitoring energy changes as part of the daily quality-assurance workflow.


Assuntos
Modelos Teóricos , Imagens de Fantasmas , Controle de Qualidade , Radiometria/instrumentação , Raios X , Dosagem Radioterapêutica
5.
Phys Med ; 82: 1-6, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33508632

RESUMO

PURPOSE: Existing phantom-less quality assurance (QA) platforms does not provide patient-specific QA for helical tomotherapy (HT). A new system, called TomoEQA, is presented to facilitate this using the leaf open time (LOT) of a binary multi-leaf collimator, as measured by an exit detector. METHODS: TomoEQA was designed to provide measurement-based LOTs based on detector data and to generate a new digital imaging and communication in medicine (DICOM) dataset that includes the measured LOTs for use by secondary check platforms. To evaluate the system, 20 patient-specific QAs were performed using the program in Mobius3D software, and the results were compared to conventional phantom-based QA results. RESULTS: From our assessment, most of the differences between the planned and measured (or calculated) data, excluding one case, were within the acceptance criteria comparing with those of conventional QA. Regarding the gamma analysis, all results considered in this study were within the acceptance criteria. In addition, the developed system was performed for a failed case and showed approximately the same trends as the conventional approach. CONCLUSIONS: TomoEQA could perform patient-specific QAs of HT using Mobius3D and provide reliable patient-specific QAs results by evaluating point dose errors and 3D gamma passing rates. TomoEQA could also distinguish whether an intensity-modulated radiation therapy plan failed or not.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Software
6.
Technol Cancer Res Treat ; 19: 1533033820979692, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33302821

RESUMO

PURPOSE: This study aimed to investigate the parameters with a significant impact on delivery quality assurance (DQA) failure and analyze the planning parameters as possible predictors of DQA failure for helical tomotherapy. METHODS: In total, 212 patients who passed or failed DQA measurements were retrospectively included in this study. Brain (n = 43), head and neck (n = 37), spinal (n = 12), prostate (n = 36), rectal (n = 36), pelvis (n = 13), cranial spinal irradiation and a treatment field including lymph nodes (n = 24), and other types of cancer (n = 11) were selected. The correlation between DQA results and treatment planning parameters were analyzed using logistic regression analysis. Receiver operating characteristic (ROC) curves, areas under the curves (AUCs), and the Classification and Regression Tree (CART) algorithm were used to analyze treatment planning parameters as possible predictors for DQA failure. RESULTS: The AUC for leaf open time (LOT) was 0.70, and its cut-off point was approximately 30%. The ROC curve for the predicted probability calculated when the multivariate variable model was applied showed an AUC of 0.815. We confirmed that total monitor units, total dose, and LOT were significant predictors for DQA failure using the CART. CONCLUSIONS: The probability of DQA failure was higher when the percentage of LOT below 100 ms was higher than 30%. The percentage of LOT below 100 ms should be considered in the treatment planning process. The findings from this study may assist in the prediction of DQA failure in the future.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Intensidade Modulada/normas , Área Sob a Curva , Tomada de Decisão Clínica , Interpretação Estatística de Dados , Gerenciamento Clínico , Fracionamento da Dose de Radiação , Humanos , Neoplasias/radioterapia , Prognóstico , Curva ROC , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Falha de Tratamento , Resultado do Tratamento
7.
PLoS One ; 15(12): e0234829, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33270667

RESUMO

BACKGROUND: This study investigated the effect of accumulated doses on radio-photoluminescence glass dosimeters (RPLGDs) from measurements involving mega-voltage photons. METHODS: Forty-five commercially available RPLGDs were irradiated to estimate their dose responses. Photon beams of 6, 10, and 15 MV were irradiated onto the RPLGDs inside a phantom, which were divided into five groups with different doses and energies. Groups 1 and 2 were irradiated at 1, 5, 10, 50, and 100 Gy in a sequential manner; Group 3 was irradiated 10 times with a dose of 10 Gy; and Groups 4 and 5 followed the same method as that of Group 3, but with doses of 50 Gy and 100 Gy, respectively. Each device was subjected to a measurement reading procedure each time irradiation. RESULTS: For the annealed Group 1, RPLGD exhibited a linearity response with variance within 5%. For the non-annealed Group 2, readings demonstrated hyperlinearity at 6 MV and 10 MV, and linearity at 15 MV. Following the 100 Gy irradiation, the readings for Group 2 were 118.7 ± 1.9%, 112.2 ± 2.7%, and 101.5 ± 2.3% at 6, 10, and 15 MV, respectively. For Groups 3, 4, and 5, the responsiveness of the RPLGDs gradually decreased as the number of repeated irradiations increased. The percentage readings for the 10th beam irradiation with respect to the readings for the primary beam irradiation were 84.6 ± 1.9%, 87.5 ± 2.4%, and 93.0 ± 3.0% at 6 MV, 10 MV, and 15 MV, respectively. CONCLUSIONS: The non-annealed RPLGD response to dose was hyperlinear for the 6 MV and 10 MV photon beams but not for the 15 MV photon beam. Additionally, the annealed RPLGD exhibited a fading phenomenon when the measurement was repeated several times and demonstrated a relatively large fading effect at low energies than at high energies.


Assuntos
Dosímetros de Radiação , Vidro , Imagens de Fantasmas , Fótons , Doses de Radiação , Dosagem Radioterapêutica , Sensibilidade e Especificidade
8.
Front Oncol ; 10: 578921, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33194701

RESUMO

Purpose: The European Society of Radiation & Oncology and Advisory Committee on Radiation Oncology Practice (ESTRO-ACROP) presented new guidelines for clinical target volume (CTV) delineation in post-mastectomy radiation therapy (PMRT) after implant-based immediate breast reconstruction (IBR-i). This study evaluated the dosimetric characteristics, dosimetric accuracy, and delivery accuracy of these guidelines in volumetric modulated arc therapy (VMAT). Methods and Materials: This retrospective study included 15 patients with left breast cancer who underwent mastectomy with tissue expander placement followed by PMRT. An experienced radiation oncologist delineated the CTV twice on the same image datasets based on the ESTRO-ACROP (EA-TVD) and conventional target volume delineation (C-TVD) guidelines. All VMAT plans, which used a double partial arc, were generated using six MV photons. Clinically relevant dose-volume parameters for organs at risk were compared. Dosimetric accuracy of the treatment plans and delivery accuracy were assessed. Results: Target volume of EA-TVD was significantly smaller than that of C-TVD. Although no statistically significant difference was noted in the target coverage between the two VMAT plans, EA-TVD VMAT significantly reduced the mean heart dose (3.99 ± 1.02 vs. 5.84 ± 1.78 Gy, p = 0.000), the maximum left anterior descending coronary artery (LAD) dose (9.43 ± 3.04 vs. 13.97 ± 6.04 Gy, p = 0.026), and the mean LAD dose (4.52 ± 1.31 vs. 6.35 ± 2.79 Gy, p = 0.028) compared with C-TVD VMAT. No significant difference was observed with respect to the total monitor units, plan complexity, and delivery quality assurance. Conclusions: This is the first study to show significant dose reduction for the normal heart and LAD tissue offered by the EA-TVD, while maintaining dosimetric and delivery accuracy, in PMRT after IBR-i in VMAT for left-sided breast cancer patients.

9.
Phys Med ; 80: 1-9, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33070006

RESUMO

PURPOSE: To provide practical guidelines for Mobius3D commissioning based on experiences of commissioning/clinical implementation of Mobius3D and MobiusFX as patient-specific quality assurance tools on multiple linear accelerators. METHODS: The vendor-suggested Mobius3D commissioning procedures, including beam model adjustment and dosimetric leaf gap (DLG) optimization, were performed for 6 MV X-ray beams of six Elekta linear accelerators. For the beam model adjustment, beam data, such as the percentage depth dose, off-axis ratio (OAR), and output factor (OF), were measured using a water phantom and compared to the vendor-provided reference values. DLG optimization was performed to determine an optimal DLG correction factor to minimize the mean difference between Mobius3D-calculated and measured doses for multiple volumetric modulated arc therapy (VMAT) plans. Small-field VMAT plans, in which Mobius3D has dose calculate uncertainties, were initially included in the DLG optimization, but excluded later. RESULTS: The measured beam data were consistent across the six linear accelerators. Relatively large differences between the reference and measured values were observed for the OAR at large off-axis distances (>5 cm) and for the OF for small fields (<3 × 3 cm2). The optimal DLG correction factor was 0.6 ±â€¯0.3 (range: 0.3-1.0) with small-field plans and 0.2 ±â€¯0.2 (0.0-0.5) without them. CONCLUSIONS: A reasonable agreement was found between the vendor-provided reference and measured beam models. DLG optimization results were dependent on the selection of the VMAT plans, requiring careful attention to the known dose calculation uncertainties of Mobius3D when determining a DLG correction factor.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Aceleradores de Partículas , Radiometria , Dosagem Radioterapêutica
10.
Phys Eng Sci Med ; 43(3): 1069-1075, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32700205

RESUMO

This study assesses the dosimetric leaf gap (DLG) correction factor in Mobius3D commissioning affected by a couch top platform and calculates the optimal DLG value according to the point dose difference function. DLG optimizations were performed for 3 LINAC machines and a total of 30 patient volumetric modulated arc therapy plans (i.e., 10 plans per each LINAC). Point dose calculations were performed using an automatic dose calculation system in Mobius3D as well as Mobis3D calculation using a Mobius Verification Phantom (MVP)-based quality assurance plan with a carbon fiber couch top. Subsequently, the results were compared with measurement data. The averaged point dose measured for the MVP with a couch top decreased by approximately 2% relative to that without the couch top. The average of the optimal DLG factors increased by 1.153 mm due to the couch top effect for a dose decrease of 2% at the measured point. In the procedure of Mobius beam commissioning, users should adjust the DLG correction factor using a specific phantom (including MVP) with a couch top structure. If the DLG optimization were performed by using MVP automatic dose calculation system, the factor should be increased by approximately 1.2 mm per 2% dose difference considering user's couch top effect.


Assuntos
Algoritmos , Dosagem Radioterapêutica , Relação Dose-Resposta à Radiação , Humanos , Aceleradores de Partículas , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada
11.
Phys Med ; 74: 125-132, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32464470

RESUMO

PURPOSE: To perform a detailed evaluation of dose calculation accuracy and clinical feasibility of Mobius3D. Of particular importance, multileaf collimator (MLC) modeling accuracy in the Mobius3D dose calculation algorithm was investigated. METHODS: Mobius3D was fully commissioned by following the vendor-suggested procedures, including dosimetric leaf gap (DLG) optimization. The DLG optimization determined an optimal DLG correction factor which minimized the average difference between calculated and measured doses for 13 patient volumetric-modulated arc therapy (VMAT) plans. Two sets of step-and-shoot plans were created to examine MLC and off-axis open fields modeling accuracy of the Mobius3D dose calculation algorithm: MLC test set and off-axis open field test set. The test plans were delivered to MapCHECK for the MLC tests and an ionization chamber for the off-axis open field test, and these measured doses were compared to Mobius3D-calculated doses. RESULTS: The mean difference between the calculated and measured doses across the 13 VMAT plans was 0.6% with an optimal DLG correction factor of 1.0. The mean percentage of pixels passing gamma from a 3%/1 mm gamma analysis for the MLC test set was 43.5% across the MLC tests. For the off-axis open field tests, the Mobius3D-calculated dose for 1.5 cm square field was -4.6% lower than the chamber-measured dose. CONCLUSIONS: It was demonstrated that Mobius3D has dose calculation uncertainties for small fields and MLC tongue-and-groove design is not adequately taken into consideration in Mobius3D. Careful consideration of DLG correction factor, which affects the resulting dose distributions, is required when commissioning Mobius3D for patient-specific QA.


Assuntos
Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica
12.
J Appl Clin Med Phys ; 21(6): 151-157, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32268003

RESUMO

PURPOSE: In this study, we developed a simple but useful computer program, called TomoMQA, to offer an automated quality assurance for mega-voltage computed tomography (MVCT) images generated via helical tomotherapy. METHODS: TomoMQA is written in MATLAB and contains three steps for analysis: (a) open the DICOM dataset folder generated via helical tomotherapy (i.e., TomoTherapy® and Radixact™), (b) call the baseline data for the consistency test and click the "Analysis" button (or click the "Analysis" button without the baseline data and export the results as the baseline data), and (c) print an analyzed report. The overall procedure for the QA analysis included in TomoMQA is referred from the TG-148 recommendation. Here, the tolerances for MVCT QA were implemented from TG-148 recommended values as default; however, it can be modified by a user manually. RESULTS: To test the performance of the TomoMQA program, 15 MVCTs were prepared from five helical tomotherapy machines (1 of TomoTherapy® HD, 2 of TomoTherapy® HDA, and 2 of Radixact™) in 3 months and the QA procedures were performed using TomoMQA. From our results, the evaluation revealed that the developed program can successfully perform the MVCT QA analysis irrespective of the type of helical tomotherapy equipment. CONCLUSION: We successfully developed a new automated analysis program for MVCT QA of a helical tomotherapy platform, called TomoMQA. The developed program will be made freely downloadable from the TomoMQA-dedicated website.


Assuntos
Radioterapia de Intensidade Modulada , Tomografia Computadorizada de Feixe Cônico , Humanos , Planejamento da Radioterapia Assistida por Computador
13.
Radiat Oncol ; 14(1): 233, 2019 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-31856870

RESUMO

BACKGROUND: Tomotherapy-based total body irradiation (TBI) is performed using the head-first position (HFP) and feet-first position (FFP) due to treatment length exceeding the 135 cm limit. To reduce the dosimetric variation at the match lines, we propose and verify a volumetric gradient matching technique (VGMT) by combining TomoHelical (TH) and TomoDirect (TD) modes. METHODS: Two planning CT image sets were acquired with HFP and FFP using 15 × 55 × 18 cm3 of solid water phantom. Planning target volume (PTV) was divided into upper, lower, and gradient volumes. The junction comprised 2-cm thick five and seven gradient volumes (5-GVs and 7-GVs) to create a dose distribution with a gentle slope. TH-IMRT and TD-IMRT plans were generated with 5-GVs and 7-GVs. The setup error in the calculated dose was assessed by shifting dose distribution of the FFP plan by 5, 10, 15, and 20 mm in the longitudinal direction and comparing it with the original. Doses for 95% (D95) and 5% of the PTV (D5) were calculated for all simulated setup error plans. Absolute dose measurements were performed using an ionization chamber in the junction. RESULTS: The TH&TD plan produced a linear gradient in junction volume, comparable to that of the TH&TH plan. D5 of the PTV was 110% of the prescribed dose when the FFP plan was shifted 0.7 cm and 1.2 cm in the superior direction for 5-GVs and 7-GVs. D95 of the PTV decreased to < 90% of the prescribed dose when the FF plan was shifted 1.1 cm and 1.3 cm in the inferior direction for 5-GVs and 7-GVs. The absolute measured dose showed a good correlation with the calculated dose in the gradient junction volume. The average percent difference (±SD) in all measured points was - 0.7 ± 1.6%, and the average dose variations between depths was - 0.18 ± 1.07%. CONCLUSION: VGMT can create a linear dose gradient across the junction area in both TH&TH and TH&TD and can minimize the dose sensitivity to longitudinal setup errors in tomotherapy-based TBI.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Irradiação Corporal Total/métodos , Simulação por Computador , Estudos de Viabilidade , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
14.
Phys Med ; 31(5): 553-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26048682

RESUMO

PURPOSE: This paper describes the hardware and software characteristics of a 3D optical scanner (P3DS) developed in-house. The P3DS consists of an LED light source, diffuse screen, step motor, CCD camera, and scanner management software with 3D reconstructed software. MATERIALS AND METHOD: We performed optical simulation, 2D and 3D reconstruction image testing, and pre-clinical testing for the P3DS. We developed the optical scanner with three key characteristics in mind. First, we developed a continuous scanning method to expand possible clinical applications. Second, we manufactured a collimator to improve image quality by reducing scattering from the light source. Third, we developed an optical scanner with changeable camera positioning to enable acquisition of optimal images according to the size of the gel dosimeter. RESULTS: We confirmed ray-tracing in P3DS with optic simulation and found that 2D projection and 3D reconstructed images were qualitatively similar to the phantom images. For pre-clinical tests, the dose distribution and profile showed good agreement among RTP, optical CT, and external beam radiotherapy film data for the axial and coronal views. The P3DS has shown that it can scan and reconstruct for evaluation of the gel dosimeter within 1 min. We confirmed that the P3DS system is a useful tool for the measurement of 3D dose distributions for 3D radiation therapy QA. Further experiments are needed to investigate quantitative analysis for 3D dose distribution.


Assuntos
Imageamento Tridimensional/instrumentação , Imagem Óptica/instrumentação , Medicina de Precisão/instrumentação , Doses de Radiação , Radiometria/instrumentação , Desenho de Equipamento , Humanos , Neuroma Acústico/diagnóstico por imagem , Tomografia Computadorizada por Raios X
15.
Med Dosim ; 40(4): 285-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25869936

RESUMO

The purpose of this study is to evaluate the influence of treatment-planning parameters on the quality of treatment plans in tomotherapy and to find the optimized planning parameter combinations when treating patients with prostate cancer under different performances. A total of 3 patients with prostate cancer with Eastern Cooperative Oncology Group (ECOG) performance status of 2 or 3 were included in this study. For each patient, 27 treatment plans were created using a combination of planning parameters (field width of 1, 2.5, and 5cm; pitch of 0.172, 0.287, and 0.43; and modulation factor of 1.8, 3, and 3.5). Then, plans were analyzed using several dosimetrical indices: the prescription isodose to target volume (PITV) ratio, homogeneity index (HI), conformity index (CI), target coverage index (TCI), modified dose HI (MHI), conformity number (CN), and quality factor (QF). Furthermore, dose-volume histogram of critical structures and critical organ scoring index (COSI) were used to analyze organs at risk (OAR) sparing. Interestingly, treatment plans with a field width of 1cm showed more favorable results than others in the planning target volume (PTV) and OAR indices. However, the treatment time of the 1-cm field width was 3 times longer than that of plans with a field width of 5cm. There was no substantial decrease in treatment time when the pitch was increased from 0.172 to 0.43, but the PTV indices were slightly compromised. As expected, field width had the most significant influence on all of the indices including PTV, OAR, and treatment time. For the patients with good performance who can tolerate a longer treatment time, we suggest a field width of 1cm, pitch of 0.172, and modulation factor of 1.8; for the patients with poor performance status, field width of 5cm, pitch of 0.287, and a modulation factor of 3.5 should be considered.


Assuntos
Adenocarcinoma/radioterapia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Idoso , Humanos , Masculino , Medicina de Precisão , Radioterapia de Intensidade Modulada
16.
J Appl Clin Med Phys ; 13(6): 3818, 2012 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-23149775

RESUMO

This study evaluated the mechanical accuracy of an in-house-developed couch-based tracking system (CBTS) according to respiration data. The overall delay time of the CBTS was calculated, and the accuracy, reproducibility, and loading effect of the CBTS were evaluated according to the sinusoidal waveform and various respiratory motion data of real patients with and without a volunteer weighing 75kg. The root mean square (rms) error of the accuracy, the reproducibility, and the sagging measurements were calculated for the three axes (X, Y, and Z directions) of the CBTS. The overall delay time of the CBTS was 0.251 sec. The accuracy and reproducibility in the Z direction in real patient data were poor, as indicated by high rms errors. The results of the loading effect were within 1.0 mm in all directions. This novel CBTS has the potential for clinical application for tumor tracking in radiation therapy.


Assuntos
Movimento/fisiologia , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Respiração , Humanos , Neoplasias/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
17.
Radiat Prot Dosimetry ; 140(4): 362-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20554581

RESUMO

This study examined the characteristics of the dental X-ray fluoroscopic equipment, 'DreamRay 60F', which was recently developed in Korea. The output linearity, output reproducibility, half-value layer (HVL), leakage radiation and scattered radiation were measured using an ionisation chamber. The surface dose equivalent rate and estimated dose equivalent of the operator were also calculated. The output linearity was 0.0015-0.0175 and the coefficient of variation for the output reproducibility was 0.0013-0.0074. The experimental HVL was 2.1 mm Al, and the leakage dose rate at 100 cm from the X-ray focus ranged from 2.70 to 19.66 microGy h (-1) depending on the direction. The scattered radiation doses differed significantly (1.7-16.8 times) depending on the distance and direction. If an operator is exposed for 10 min per procedure, 5 procedures a day at 5 days a week, he/she sitting at a 90 degrees direction will receive an annual dose equivalent of 13.0 mSv (at 30 cm) and 63.7 mSv (at 50 cm) in the trunk and face surface, respectively.


Assuntos
Fluoroscopia/instrumentação , Doses de Radiação , Radiografia Dentária/instrumentação , Radiometria/métodos , Desenho de Equipamento , Fluoroscopia/métodos , Humanos , Modelos Estatísticos , Exposição Ocupacional , Radiografia Dentária/métodos , Reprodutibilidade dos Testes , Raios X
18.
Radiat Prot Dosimetry ; 138(4): 382-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19959602

RESUMO

In this research, using direct measurements and Monte Carlo calculations, the potential dose reduction achieved by bismuth shielding in computed tomography was evaluated. The patient dose was measured using an ionisation chamber in a polymethylmethacrylate (PMMA) phantom that had five measurement points at the centre and periphery. Simulations were performed using the MCNPX code. For both the bare and the bismuth-shielded phantom, the differences of dose values between experiment and simulation were within 9%. The dose reductions due to the bismuth shielding were 1.2-55% depending on the measurement points, X-ray tube voltage and the type of shielding. The amount of dose reduction was significant for the positions covered by the bismuth shielding (34 - 46% for head and 41 - 55% for body phantom on average) and negligible for other peripheral positions. The artefact on the reconstructed images were minimal when the distance between the shielding and the organs was >1 cm, and hence the shielding should be selectively located to protect critical organs such as the eye lens, thyroid and breast. The simulation results using the PMMA phantom was compared with those using a realistically voxelised phantom (KTMAN-2). For eye and breast, the simulation results using the PMMA and KTMAN-2 phantoms were similar with each other, while for thyroid the simulation results were different due to the discrepancy of locations and the sizes of the phantoms. The dose reductions achieved by bismuth and lead shielding were compared with each other and the results showed that the difference of the dose reductions achieved by the two materials was less than 2-3%.


Assuntos
Bismuto/química , Simulação por Computador , Método de Monte Carlo , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Mama/efeitos da radiação , Cabeça/efeitos da radiação , Humanos , Cristalino/efeitos da radiação , Equipamentos de Proteção , Doses de Radiação , Glândula Tireoide/efeitos da radiação , Tomografia Computadorizada por Raios X/instrumentação